Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30.750
Filtrar
1.
J Neuroeng Rehabil ; 21(1): 77, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745227

RESUMEN

BACKGROUND: Over 80% of patients with stroke experience finger grasping dysfunction, affecting independence in activities of daily living and quality of life. In routine training, task-oriented training is usually used for functional hand training, which may improve finger grasping performance after stroke, while augmented therapy may lead to a better treatment outcome. As a new technology-supported training, the hand rehabilitation robot provides opportunities to improve the therapeutic effect by increasing the training intensity. However, most hand rehabilitation robots commonly applied in clinics are based on a passive training mode and lack the sensory feedback function of fingers, which is not conducive to patients completing more accurate grasping movements. A force feedback hand rehabilitation robot can compensate for these defects. However, its clinical efficacy in patients with stroke remains unknown. This study aimed to investigate the effectiveness and added value of a force feedback hand rehabilitation robot combined with task-oriented training in stroke patients with hemiplegia. METHODS: In this single-blinded randomised controlled trial, 44 stroke patients with hemiplegia were randomly divided into experimental (n = 22) and control (n = 22) groups. Both groups received 40 min/day of conventional upper limb rehabilitation training. The experimental group received 20 min/day of task-oriented training assisted by a force feedback rehabilitation robot, and the control group received 20 min/day of task-oriented training assisted by therapists. Training was provided for 4 weeks, 5 times/week. The Fugl-Meyer motor function assessment of the hand part (FMA-Hand), Action Research Arm Test (ARAT), grip strength, Modified Ashworth scale (MAS), range of motion (ROM), Brunnstrom recovery stages of the hand (BRS-H), and Barthel index (BI) were used to evaluate the effect of two groups before and after treatment. RESULTS: Intra-group comparison: In both groups, the FMA-Hand, ARAT, grip strength, AROM, BRS-H, and BI scores after 4 weeks of treatment were significantly higher than those before treatment (p < 0.05), whereas there was no significant difference in finger flexor MAS scores before and after treatment (p > 0.05). Inter-group comparison: After 4 weeks of treatment, the experimental group's FMA-Hand total score, ARAT, grip strength, and AROM were significantly better than those of the control group (p < 0.05). However, there were no statistically significant differences in the scores of each sub-item of the FMA-Hand after Bonferroni correction (p > 0.007). In addition, there were no statistically significant differences in MAS, BRS-H, and BI scores (p > 0.05). CONCLUSION: Hand performance improved in patients with stroke after 4 weeks of task-oriented training. The use of a force feedback hand rehabilitation robot to support task-oriented training showed additional value over conventional task-oriented training in stroke patients with hand dysfunction. CLINICAL TRIAL REGISTRATION INFORMATION: NCT05841108.


Asunto(s)
Fuerza de la Mano , Hemiplejía , Robótica , Rehabilitación de Accidente Cerebrovascular , Humanos , Rehabilitación de Accidente Cerebrovascular/métodos , Rehabilitación de Accidente Cerebrovascular/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Robótica/instrumentación , Fuerza de la Mano/fisiología , Hemiplejía/rehabilitación , Hemiplejía/fisiopatología , Hemiplejía/etiología , Anciano , Método Simple Ciego , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/fisiopatología , Dedos/fisiología , Dedos/fisiopatología , Mano/fisiopatología , Adulto , Retroalimentación Sensorial/fisiología , Resultado del Tratamiento , Recuperación de la Función
2.
PLoS One ; 19(5): e0301529, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38743734

RESUMEN

African elephants have a wide range of abilities using their trunk. As a muscular hydrostat, and thanks to the two finger-like processes at its tip, this proboscis can both precisely grasp and exert considerable force by wrapping. Yet few studies have attempted to quantify its distal grasping force. Thus, using a device equipped with force sensors and an automatic reward system, the trunk tip pinch force has been quantified in five captive female African savanna elephants. Results showed that the maximum pinch force of the trunk was 86.4 N, which may suggest that this part of the trunk is mainly dedicated to precision grasping. We also highlighted for the first time a difference in force between the two fingers of the trunk, with the dorsal finger predominantly stronger than the ventral finger. Finally, we showed that the position of the trunk, particularly the torsion, influences its force and distribution between the two trunk fingers. All these results are discussed in the light of the trunk's anatomy, and open up new avenues for evolutionary reflection and soft robot grippers.


Asunto(s)
Elefantes , Animales , Elefantes/fisiología , Femenino , Torso/fisiología , Torso/anatomía & histología , Dedos/fisiología , Dedos/anatomía & histología , Fuerza de la Mano/fisiología , Fenómenos Biomecánicos
3.
J Coll Physicians Surg Pak ; 34(5): 600-603, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38720223

RESUMEN

OBJECTIVE: To investigate whether there is a relationship between the 2nd finger and 4th finger length measurement ratios and developmental dysplasia of the Hip (DDH). STUDY DESIGN: Cross-sectional observational study. Place and Duration of the Study: Department of Orthopaedics and Traumatology, Meram Faculty of Medicine Hospital, Konya, Turkiye, from January 2020 to May 2023. METHODOLOGY: Infants were screened for DDH with Graff method for the ultrasounds of both hips. Lengths of the 2nd and 4th fingers of both hands were measured and recorded. Patients with additional risk factors for developmental dysplasia of the hip (breech birth, family history, oligohydramnios, swaddling) were excluded. RESULTS: Two hundred and fifty-six babies were screened including 55.1% (n = 141) girls and 44.9% (n = 115) boys. Their mean age was 2.51 ± 0.80 months. The average lengths were 31.73 ± 3.05 mm, for the left 2nd finger and 34.26 ± 3.48 mm for the left 4th finger. In the hip USG measurements, the mean alpha angles were 62.91 ± 3.12° for the right hip and, 63.20 ± 3.55° for the left hip. Eighteen (7%) of babies who underwent hip ultrasound (USG) had unilateral or bilateral DDH. Among these cases, 2.7% (n = 7) had right, 2.3% (n = 6) had left, and 2% (n = 5) had bilateral DDH. There was no statistically significant correlation between the ratios of right 2/4 finger lengths and the right alpha angle (rs = 0.051; p = 0.421). There was a statistically positive and statistically significant correlation between the ratios of left 2/4 finger lengths and the left alpha angle (rs = 0.154; p = 0.013). CONCLUSION: Only the left-hand finger ratio among the parameters in the model had a statistically significant effect on DDH. Therefore, the left hand 2D/4D finger length may be of value in screening for DDH. KEY WORDS: Developmental dysplasia of the hip, Second to fourth finger digit ratio, Ring finger, Digit ratios.


Asunto(s)
Displasia del Desarrollo de la Cadera , Dedos , Ultrasonografía , Humanos , Femenino , Masculino , Estudios Transversales , Displasia del Desarrollo de la Cadera/diagnóstico por imagen , Dedos/anomalías , Dedos/diagnóstico por imagen , Dedos/anatomía & histología , Lactante , Tamizaje Neonatal/métodos , Recién Nacido , Luxación Congénita de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/diagnóstico , Luxación Congénita de la Cadera/epidemiología , Tamizaje Masivo/métodos
4.
Med Eng Phys ; 127: 104168, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38692764

RESUMEN

Skin color observation provides a simple and non-invasive method to estimate the health status of patients. Capillary Refill Time (CRT) is widely used as an indicator of pathophysiological conditions, especially in emergency patients. While the measurement of CRT is easy to perform, its evaluation is highly subjective. This study proposes a method to aid quantified CRT measurement using an RGB camera. The procedure consists in applying finger compression to the forearm, and the CRT is calculated based on the skin color change after the pressure release. We estimate compression applied by a finger from its fingernail color change during compression. Our study shows a step towards camera-based quantitative CRT for untrained individuals.


Asunto(s)
Capilares , Dedos , Dedos/irrigación sanguínea , Dedos/fisiología , Humanos , Capilares/fisiología , Capilares/diagnóstico por imagen , Factores de Tiempo , Presión , Masculino , Adulto , Fenómenos Mecánicos , Femenino
5.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38732790

RESUMEN

With the development of biometric identification technology, finger vein identification has received more and more widespread attention for its security, efficiency, and stability. However, because of the performance of the current standard finger vein image acquisition device and the complex internal organization of the finger, the acquired images are often heavily degraded and have lost their texture characteristics. This makes the topology of the finger veins inconspicuous or even difficult to distinguish, greatly affecting the identification accuracy. Therefore, this paper proposes a finger vein image recovery and enhancement algorithm using atmospheric scattering theory. Firstly, to normalize the local over-bright and over-dark regions of finger vein images within a certain threshold, the Gamma transform method is improved in this paper to correct and measure the gray value of a given image. Then, we reconstruct the image based on atmospheric scattering theory and design a pixel mutation filter to segment the venous and non-venous contact zones. Finally, the degraded finger vein images are recovered and enhanced by global image gray value normalization. Experiments on SDUMLA-HMT and ZJ-UVM datasets show that our proposed method effectively achieves the recovery and enhancement of degraded finger vein images. The image restoration and enhancement algorithm proposed in this paper performs well in finger vein recognition using traditional methods, machine learning, and deep learning. The recognition accuracy of the processed image is improved by more than 10% compared to the original image.


Asunto(s)
Algoritmos , Dedos , Procesamiento de Imagen Asistido por Computador , Venas , Humanos , Dedos/irrigación sanguínea , Dedos/diagnóstico por imagen , Venas/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Identificación Biométrica/métodos , Atmósfera
6.
J Assoc Physicians India ; 72(1): 99-102, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38736082

RESUMEN

BACKGROUND: Peripheral T cell lymphoma (PTCL), not otherwise specified (NOS) is a heterogenous group of predominantly nodal T cell lymphomas that generally presents with lymphadenopathy with or without extra nodal involvement. Acral vascular syndrome clinically presents as digital ischemia with Raynaud's phenomenon and acral cyanosis. Although, this condition is commonly associated with connective tissue disorder, smoking and vasculitis, its association with lymphoid malignancy is very rare. Here, we present a case report of a patient with digital gangrene of all toes and fingers as a presenting symptom of PTCL-NOS. CASE DESCRIPTION: A 62 year old male presented with digital ischemia associated with pain, low grade fever, loss of appetite and significant weight loss of 6 kilograms over a period of 3 months. On examination, he was found to have bilateral inguinal and axillary lymph nodes with gangrenous changes over toes and fingers but peripheral pulses were palpable. On evaluation he had anemia, elevated ESR and CRP. CT angiogram revealed thinned out digital arteries with multifocal areas of narrowing. Patient was screened for other causes of digital gangrene and was tested negative for ANCA, ANA, cryoglobulins and viral markers. Lymph node biopsy with IHC was suggestive of peripheral T-cell lymphoma-NOS and was started on CHOP regimen. Lymph nodes size decreased and gangrenous changes resolved. CONCLUSION: Though digital ischemia is a rare paraneoplastic presentation of lymphoma, it should be considered if there is a rapid progression of gangrene. Early initiation of chemotherapy may result in the reduction of further progression of digital gangrene and thus prevent permanent disability. In our patient, progression of gangrene was prevented even though it was an aggressive variant of T cell lymphoma.


Asunto(s)
Dedos , Gangrena , Linfoma de Células T Periférico , Síndromes Paraneoplásicos , Dedos del Pie , Humanos , Masculino , Gangrena/etiología , Gangrena/diagnóstico , Linfoma de Células T Periférico/diagnóstico , Linfoma de Células T Periférico/complicaciones , Persona de Mediana Edad , Dedos/patología , Síndromes Paraneoplásicos/diagnóstico , Síndromes Paraneoplásicos/etiología , Dedos del Pie/patología , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Ciclofosfamida/uso terapéutico , Doxorrubicina/uso terapéutico , Vincristina/uso terapéutico , Prednisona/uso terapéutico
7.
Cereb Cortex ; 34(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38642106

RESUMEN

The spatial coding of tactile information is functionally essential for touch-based shape perception and motor control. However, the spatiotemporal dynamics of how tactile information is remapped from the somatotopic reference frame in the primary somatosensory cortex to the spatiotopic reference frame remains unclear. This study investigated how hand position in space or posture influences cortical somatosensory processing. Twenty-two healthy subjects received electrical stimulation to the right thumb (D1) or little finger (D5) in three position conditions: palm down on right side of the body (baseline), hand crossing the body midline (effect of position), and palm up (effect of posture). Somatosensory-evoked potentials (SEPs) were recorded using electroencephalography. One early-, two mid-, and two late-latency neurophysiological components were identified for both fingers: P50, P1, N125, P200, and N250. D1 and D5 showed different cortical activation patterns: compared with baseline, the crossing condition showed significant clustering at P1 for D1, and at P50 and N125 for D5; the change in posture showed a significant cluster at N125 for D5. Clusters predominated at centro-parietal electrodes. These results suggest that tactile remapping of fingers after electrical stimulation occurs around 100-125 ms in the parietal cortex.


Asunto(s)
Percepción del Tacto , Tacto , Humanos , Tacto/fisiología , Dedos/fisiología , Percepción del Tacto/fisiología , Mano/fisiología , Electroencefalografía , Corteza Somatosensorial
8.
Biosensors (Basel) ; 14(4)2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38667198

RESUMEN

Wearable health devices (WHDs) are rapidly gaining ground in the biomedical field due to their ability to monitor the individual physiological state in everyday life scenarios, while providing a comfortable wear experience. This study introduces a novel wearable biomedical device capable of synchronously acquiring electrocardiographic (ECG), photoplethysmographic (PPG), galvanic skin response (GSR) and motion signals. The device has been specifically designed to be worn on a finger, enabling the acquisition of all biosignals directly on the fingertips, offering the significant advantage of being very comfortable and easy to be employed by the users. The simultaneous acquisition of different biosignals allows the extraction of important physiological indices, such as heart rate (HR) and its variability (HRV), pulse arrival time (PAT), GSR level, blood oxygenation level (SpO2), and respiratory rate, as well as motion detection, enabling the assessment of physiological states, together with the detection of potential physical and mental stress conditions. Preliminary measurements have been conducted on healthy subjects using a measurement protocol consisting of resting states (i.e., SUPINE and SIT) alternated with physiological stress conditions (i.e., STAND and WALK). Statistical analyses have been carried out among the distributions of the physiological indices extracted in time, frequency, and information domains, evaluated under different physiological conditions. The results of our analyses demonstrate the capability of the device to detect changes between rest and stress conditions, thereby encouraging its use for assessing individuals' physiological state. Furthermore, the possibility of performing synchronous acquisitions of PPG and ECG signals has allowed us to compare HRV and pulse rate variability (PRV) indices, so as to corroborate the reliability of PRV analysis under stationary physical conditions. Finally, the study confirms the already known limitations of wearable devices during physical activities, suggesting the use of algorithms for motion artifact correction.


Asunto(s)
Electrocardiografía , Dedos , Respuesta Galvánica de la Piel , Frecuencia Cardíaca , Fotopletismografía , Dispositivos Electrónicos Vestibles , Humanos , Monitoreo Fisiológico/instrumentación , Procesamiento de Señales Asistido por Computador , Masculino , Adulto , Femenino
9.
Sensors (Basel) ; 24(8)2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38676202

RESUMEN

Haptic hands and grippers, designed to enable skillful object manipulation, are pivotal for high-precision interaction with environments. These technologies are particularly vital in fields such as minimally invasive surgery, where they enhance surgical accuracy and tactile feedback: in the development of advanced prosthetic limbs, offering users improved functionality and a more natural sense of touch, and within industrial automation and manufacturing, they contribute to more efficient, safe, and flexible production processes. This paper presents the development of a two-finger robotic hand that employs simple yet precise strategies to manipulate objects without damaging or dropping them. Our innovative approach fused force-sensitive resistor (FSR) sensors with the average current of servomotors to enhance both the speed and accuracy of grasping. Therefore, we aim to create a grasping mechanism that is more dexterous than grippers and less complex than robotic hands. To achieve this goal, we designed a two-finger robotic hand with two degrees of freedom on each finger; an FSR was integrated into each fingertip to enable object categorization and the detection of the initial contact. Subsequently, servomotor currents were monitored continuously to implement impedance control and maintain the grasp of objects in a wide range of stiffness. The proposed hand categorized objects' stiffness upon initial contact and exerted accurate force by fusing FSR and the motor currents. An experimental test was conducted using a Yale-CMU-Berkeley (YCB) object set consisted of a foam ball, an empty soda can, an apple, a glass cup, a plastic cup, and a small milk packet. The robotic hand successfully picked up these objects from a table and sat them down without inflicting any damage or dropping them midway. Our results represent a significant step forward in developing haptic robotic hands with advanced object perception and manipulation capabilities.


Asunto(s)
Dedos , Fuerza de la Mano , Robótica , Tacto , Robótica/métodos , Robótica/instrumentación , Humanos , Dedos/fisiología , Tacto/fisiología , Fuerza de la Mano/fisiología , Impedancia Eléctrica , Mano/fisiología , Diseño de Equipo
10.
Sensors (Basel) ; 24(8)2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38676245

RESUMEN

Fingerprint recognition systems have achieved widespread integration into various technological devices, including cell phones, computers, door locks, and time attendance machines. Nevertheless, individuals with worn fingerprints encounter challenges when attempting to unlock original fingerprint systems, which results in disruptions to their daily activities. This study explores two distinct methods for fingerprint backup: traditional fingerprint impression and 3D printing technologies. Unlocking tests were conducted on commonly available optical fingerprint lock-equipped cell phones to assess the efficacy of these methods, particularly in unlocking with worn fingerprints. The research findings indicated that the traditional fingerprint impression method exhibited high fidelity in reproducing fingerprint patterns, achieving an impressive unlocking success rate of 97.8% for imprinting unworn fingerprints. However, when dealing with worn fingerprints, the traditional fingerprint impression technique showed a reduced unlocking success rate, progressively decreasing with increasing degrees of finger wear. In contrast, 3D-printed backup fingerprints, with image processing and optimization of ridge height, mitigated the impact of fingerprint wear on the unlocking capability, resulting in an unlocking success rate of 84.4% or higher. Thus, the utilization of 3D printing technology proves advantageous for individuals with severely worn or incomplete fingerprints, providing a viable solution for unforeseen circumstances.


Asunto(s)
Dermatoglifia , Impresión Tridimensional , Humanos , Dedos/fisiología , Procesamiento de Imagen Asistido por Computador/métodos
11.
Sensors (Basel) ; 24(7)2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38610340

RESUMEN

In this study, an internal fingerprint-guided epidermal thickness of fingertip skin is proposed for optical image encryption based on optical coherence tomography (OCT) combined with U-Net architecture of a convolutional neural network (CNN). The epidermal thickness of fingertip skin is calculated by the distance between the upper and lower boundaries of the epidermal layer in cross-sectional optical coherence tomography (OCT) images, which is segmented using CNN, and the internal fingerprint at the epidermis-dermis junction (DEJ) is extracted based on the maximum intensity projection (MIP) algorithm. The experimental results indicate that the internal fingerprint-guided epidermal thickness is insensitive to pressure due to normal correlation coefficients and the encryption process between epidermal thickness maps of fingertip skin under different pressures. In addition, the result of the numerical simulation demonstrates the feasibility and security of the encryption scheme by structural similarity index matrix (SSIM) analysis between the original image and the recovered image with the correct and error keys decryption, respectively. The robustness is analyzed based on the SSIM value in three aspects: different pressures, noise attacks, and data loss. Key randomness is valid by the gray histograms, and the average correlation coefficients of adjacent pixelated values in three directions and the average entropy were calculated. This study suggests that the epidermal thickness of fingertip skin could be seen as important biometric information for information encryption.


Asunto(s)
Epidermis , Dedos , Estudios Transversales , Epidermis/diagnóstico por imagen , Dedos/diagnóstico por imagen , Algoritmos , Biometría
12.
Medicine (Baltimore) ; 103(16): e37868, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38640291

RESUMEN

RATIONALE: The conventional treatment of giant cell tumors is intralesional curettage with local adjuvant therapy. Because hand tumors have a high local recurrence, the primary goal for treating tumors of the hand is to eradicate the lesion. PATIENT CONCERNS: To preserve the metacarpophalangeal (MCP) joint function as well as avoid further recurrence after surgery. DIAGNOSES: The giant cell tumor invades the patient's MCP joint in an index proximal phalanx. INTERVENTIONS: Using computer-aided design and three-dimensional printing techniques, we reformed the original shapes of the MCP joint and its peripheral bone to replica models. The surgeon then performed an en bloc resection and proximal phalanx with MCP joint reconstruction by fabricating the patient's costal osteochondral graft during the operation. OUTCOMES: After 6 months of rehabilitation, the patient's finger functions could pinch and grasp objects naturally. At the 1-year follow-up, the range of motion of the MCP, proximal interphalangeal, and distal interphalangeal joints improved from flexion of 35° to 60°, 75° to 85°, and 60° to 80°, respectively. The hand function achieved the mean performance of non-preferred hands for young females at the postoperative 3-year follow-up. LESSONS: The customized prototyping technique has the potential to replica the original patient's bony graft to reach the goal of minimizing the defects at the donor site and maximizing the function of the reconstructed MCP joint.


Asunto(s)
Prótesis Articulares , Neoplasias , Femenino , Humanos , Dedos , Costillas/trasplante , Articulación Metacarpofalángica/cirugía , Rango del Movimiento Articular , Articulaciones de los Dedos/cirugía
13.
Neurorehabil Neural Repair ; 38(5): 373-385, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38572686

RESUMEN

BACKGROUND: Knowing how impaired manual dexterity and finger proprioception affect upper limb activity capacity is important for delineating targeted post-stroke interventions for upper limb recovery. OBJECTIVES: To investigate whether impaired manual dexterity and finger proprioception explain variance in post-stroke activity capacity, and whether they explain more variance than conventional clinical assessments of upper limb sensorimotor impairments. METHODS: Activity capacity and hand sensorimotor impairments were assessed using clinical measures in N = 42 late subacute/chronic hemiparetic stroke patients. Dexterity was evaluated using the Dextrain Manipulandum to quantify accuracy of visuomotor finger force-tracking (N = 36), timing of rhythmic tapping (N = 36), and finger individuation (N = 24), as well as proprioception (N = 27). Stepwise multivariate and hierarchical linear regression models were used to identify impairments best explaining activity capacity. RESULTS: Dexterity and proprioceptive components significantly increased the variance explained in activity capacity: (i) Box and Block Test was best explained by baseline tonic force during force-tracking and tapping frequency (adjusted R2 = .51); (ii) Motor Activity Log was best explained by success rate in finger individuation (adjusted R2 = .46); (iii) Action Research Arm Test was best explained by release of finger force and proprioceptive measures (improved reaction time related to use of proprioception; adjusted R2 = .52); and (iv) Moberg Pick-Up test was best explained by proprioceptive function (adjusted R2 = .18). Models excluding dexterity and proprioception variables explained up to 19% less variance. CONCLUSIONS: Manual dexterity and finger proprioception explain unique variance in activity capacity not captured by conventional impairment measures and should be assessed when considering the underlying causes of post-stroke activity capacity limitations.URL: https://www.clinicaltrials.gov. Unique identifier: NCT03934073.


Asunto(s)
Dedos , Propiocepción , Accidente Cerebrovascular , Extremidad Superior , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dedos/fisiopatología , Dedos/fisiología , Actividad Motora/fisiología , Destreza Motora/fisiología , Paresia/fisiopatología , Paresia/etiología , Propiocepción/fisiología , Accidente Cerebrovascular/fisiopatología , Accidente Cerebrovascular/complicaciones , Extremidad Superior/fisiopatología
14.
Bioinspir Biomim ; 19(3)2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38579732

RESUMEN

In the field of robotic hands, finger force coordination is usually achieved by complex mechanical structures and control systems. This study presents the design of a novel transmission system inspired from the physiological concept of force synergies, aiming to simplify the control of multifingered robotic hands. To this end, we collected human finger force data during six isometric grasping tasks, and force synergies (i.e. the synergy weightings and the corresponding activation coefficients) were extracted from the concatenated force data to explore their potential for force modulation. We then implemented two force synergies with a cable-driven transmission mechanism consisting of two spring-loaded sliders and five V-shaped bars. Specifically, we used fixed synergy weightings to determine the stiffness of the compression springs, and the displacements of sliders were determined by time-varying activation coefficients. The derived transmission system was then used to drive a five-finger robotic hand named SYN hand. We also designed a motion encoder to selectively activate desired fingers, making it possible for two motors to empower a variety of hand postures. Experiments on the prototype demonstrate successful grasp of a wide range of objects in everyday life, and the finger force distribution of SYN hand can approximate that of human hand during six typical tasks. To our best knowledge, this study shows the first attempt to mechanically implement force synergies for finger force modulation in a robotic hand. In comparison to state-of-the-art robotic hands with similar functionality, the proposed hand can distribute humanlike force ratios on the fingers by simple position control, rather than resorting to additional force sensors or complex control strategies. The outcome of this study may provide alternatives for the design of novel anthropomorphic robotic hands, and thus show application prospects in the field of hand prostheses and exoskeletons.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Mano/fisiología , Dedos/fisiología , Fuerza de la Mano
15.
Artículo en Inglés | MEDLINE | ID: mdl-38681505

RESUMEN

Background: Posterior interosseous neuropathy is an uncommon cause of peripheral dystonia. Case Report: A 62-year-old man awakened and noticed right finger drop. A neurological examination revealed posterior interosseous neuropathy with dystonia-like finger movements. Abnormal movements were predominantly observed in the right thumb, ring finger, and little finger. Within 2 weeks, the muscle weakness in the right fingers had completely improved. However, a brief abnormal posture of the right thumb was persistent. Discussion: The residual abnormal posture of the right thumb may reflect pre-existing motor control abnormalities, which may have contributed to the onset of posterior interosseous neuropathy-associated peripheral dystonia.


Asunto(s)
Distonía , Humanos , Masculino , Persona de Mediana Edad , Distonía/fisiopatología , Distonía/etiología , Trastornos Distónicos/fisiopatología , Trastornos Distónicos/complicaciones , Trastornos Distónicos/diagnóstico , Enfermedades del Sistema Nervioso Periférico/fisiopatología , Enfermedades del Sistema Nervioso Periférico/complicaciones , Enfermedades del Sistema Nervioso Periférico/etiología , Enfermedades del Sistema Nervioso Periférico/diagnóstico , Dedos/fisiopatología
16.
Sci Rep ; 14(1): 9206, 2024 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-38649731

RESUMEN

Periodic quantification of blood glucose levels is performed using painful, invasive methods. The proposed work presents the development of a noninvasive glucose-monitoring device with two sensors, i.e., finger and wrist bands. The sensor system was designed with a near-infrared (NIR) wavelength of 940 nm emitter and a 900-1700 nm detector. This study included 101 diabetic and non-diabetic volunteers. The obtained dataset was subjected to pre-processing, exploratory data analysis (EDA), data visualization, and integration methods. Ambiguities such as the effects of skin color, ambient light, and finger pressure on the sensor were overcome in the proposed 'niGLUC-2.0v'. niGLUC-2.0v was validated with performance metrics where accuracy of 99.02%, mean absolute error (MAE) of 0.15, mean square error (MSE) of 0.22 for finger, and accuracy of 99.96%, MAE of 0.06, MSE of 0.006 for wrist prototype with ridge regression (RR) were achieved. Bland-Altman analysis was performed, where 98% of the data points were within ± 1.96 standard deviation (SD), 100% were under zone A of the Clarke Error Grid (CEG), and statistical analysis showed p < 0.05 on evaluated accuracy. Thus, niGLUC-2.0v is suitable in the medical and personal care fields for continuous real-time blood glucose monitoring.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Humanos , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Masculino , Femenino , Adulto , Dedos , Persona de Mediana Edad , Muñeca , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Diabetes Mellitus/sangre , Diabetes Mellitus/diagnóstico
17.
Aging Clin Exp Res ; 36(1): 87, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38578525

RESUMEN

BACKGROUND: The multifinger force deficit (MFFD) is the decline in force generated by each finger as the number of fingers contributing to an action is increased. It has been shown to associate with cognitive status. AIMS: The aim was to establish whether a particularly challenging form of multifinger grip dynamometry, that provides minimal tactile feedback via cutaneous receptors and requires active compensation for reaction forces, will yield an MFFD that is more sensitive to cognitive status. METHODS: Associations between measures of motor function, and cognitive status (Montreal Cognitive Assessment [MoCA]) and latent components of cognitive function (derived from 11 tests using principal component analysis), were estimated cross-sectionally using generalized partial rank correlations. The participants (n = 62) were community dwelling, aged 65-87. RESULTS: Approximately half the participants were unable to complete the dynamometry task successfully. Cognitive status demarcated individuals who could perform the task from those who could not. Among those who complied with the task requirements, the MFFD was negatively correlated with MoCA scores-those with the highest MoCA scores tended to exhibit the smallest deficits, and vice versa. There were corresponding associations with latent components of cognitive function. DISCUSSION: The results support the view that neurodegenerative processes that are a feature of normal and pathological aging exert corresponding effects on expressions of motor coordination-in multifinger tasks, and cognitive sufficiency, due to their dependence on shared neural systems. CONCLUSIONS: The outcomes add weight to the assertion that deficits in force production during multifinger tasks are sensitive to cognitive dysfunction.


Asunto(s)
Disfunción Cognitiva , Fuerza de la Mano , Humanos , Fuerza de la Mano/fisiología , Envejecimiento , Dedos/fisiología , Análisis de Componente Principal
18.
Sci Rep ; 14(1): 8145, 2024 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-38584229

RESUMEN

Photoplethysmography (PPG) uses light to detect volumetric changes in blood, and is integrated into many healthcare devices to monitor various physiological measurements. However, an unresolved limitation of PPG is the effect of skin pigmentation on the signal and its impact on PPG based applications such as pulse oximetry. Hence, an in-silico model of the human finger was developed using the Monte Carlo (MC) technique to simulate light interactions with different melanin concentrations in a human finger, as it is the primary determinant of skin pigmentation. The AC/DC ratio in reflectance PPG mode was evaluated at source-detector separations of 1 mm and 3 mm as the convergence rate (Q), a parameter that quantifies the accuracy of the simulation, exceeded a threshold of 0.001. At a source-detector separation of 3 mm, the AC/DC ratio of light skin was 0.472 times more than moderate skin and 6.39 than dark skin at 660 nm, and 0.114 and 0.141 respectively at 940 nm. These findings are significant for the development of PPG-based sensors given the ongoing concerns regarding the impact of skin pigmentation on healthcare devices.


Asunto(s)
Melaninas , Fotopletismografía , Humanos , Fotopletismografía/métodos , Método de Montecarlo , Oximetría/métodos , Dedos/fisiología
19.
J Sports Sci ; 42(5): 392-403, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38574326

RESUMEN

When applied over the primary motor cortex (M1), anodal transcranial direct current stimulation (a-tDCS) could enhance the effects of a single motor imagery training (MIt) session on the learning of a sequential finger-tapping task (SFTT). This study aimed to investigate the effect of a-tDCS on the learning of an SFTT during multiple MIt sessions. Two groups of 16 healthy young adults participated in three consecutive MIt sessions over 3 days, followed by a retention test 1 week later. They received active or sham a-tDCS during a MIt session in which they mentally rehearsed an eight-item complex finger sequence with their left hand. Before and after each session, and during the retention test, they physically repeated the sequence as quickly and accurately as possible. Both groups (i) improved their performance during the first two sessions, showing online learning; (ii) stabilised the level they reached during all training sessions, reflecting offline consolidation; and (iii) maintained their performance level one week later, showing retention. However, no significant difference was found between the groups, regardless of the MSL stage. These results emphasise the importance of performing several MIt sessions to maximise performance gains, but they do not support the additional effects of a-tDCS.


Asunto(s)
Dedos , Aprendizaje , Corteza Motora , Estimulación Transcraneal de Corriente Directa , Humanos , Adulto Joven , Masculino , Corteza Motora/fisiología , Femenino , Aprendizaje/fisiología , Dedos/fisiología , Adulto , Destreza Motora/fisiología , Imaginación/fisiología , Desempeño Psicomotor/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA